In operational amplifier stability, one rule of thumb is to allow 45 degrees of phase margin. Other design guidelines state that 60 degrees is best; still others say that 30 degrees is sufficient.
The phase determines the oscillation frequency, and gain is a criterion for oscillation to exist. The four poles in the loop equation each contribute –45° phase shift accumulating the required total ...